HPE Superdome Flex 280 servers base_io issue

 

Recently built HPE Superdome Flex 280 servers and observed below error on ILO console and called as RMC also.




To resolve the issue, we need to login ILO console IP via putty session and run the below commands one by one. it will clear the alert.

Login to RMC

RMC cli> show indict
RMC cli> acquit physloc=FFFF04010XXXX
RMC cli> show indict



How to collect acquit physloc details


RMC cli> show indict


==== r001i01a ====

  FFFF000401FFEE84 rack1/chassis_u1/harp_fan0

    Indicted: Yes
          2017-10-31T17:05:42Z Reason ID: 302
		  Summary: Fan reported to be running slowly or stopped
		  Cause: A fan is not running at normal speed. There may be
               something obstructing the airflow, a blocked fan or a fan failure.
		  Action: Check the enclosure for obstructions to airflow and ensure the 
		  fans are installed properly. If the problem persists, replace
               the fan. After replacing the faulty fan, perform an acquittal from the RMC
               command line.            

RMC cli> acquit physloc=FFFF000401FFEE84